Computes the power of the F test of an intraclass correlation
coefficient (ICC) used by icc_test(), or solves for the number of
subjects, the number of measurements per subject, the ICC under the
alternative, or the significance level that gives a target power. Exactly
one of n, k, rho1, power and sig.level must be NULL; that one
is computed from the others, as in stats::power.t.test().
Arguments
- n
Number of subjects.
- k
Number of measurements (items: trials, raters or occasions) per subject. When solved for, the smallest whole number of at least 2 that reaches the target is returned.
- rho0
The ICC under the null hypothesis (default 0).
- rho1
The ICC under the alternative hypothesis.
- sig.level
Significance level (Type I error rate; default 0.05).
- power
Power of the test (1 minus the Type II error rate).
- model
"oneway"(default) or"twoway"."twoway"means the consistency ICC, ICC(C,1) oficc_test(); the absolute agreement ICC is not supported (see Details).- unit
"single"(default) for the reliability of a single measurement, or"average"for the reliability of the mean of thekmeasurements (ICC(k) or ICC(C,k)), as inicc_test(). With"average", the ICC values are on the average-measure scale andkcannot be solved for. See Details.- missing
The expected proportion of measurements (subject-by-item cells) that will be missing, analysed with
icc_test(method = "reml"). The default, 0, gives the exact complete-data calculation; values above 0 give an approximation (see Details). For subjects who will be lost entirely, reduceninstead.- alternative
"two.sided"(default),"greater", or"less", as inicc_test(). A design planned with the defaults matches the analysis run with the defaults.- method
"exact"(default) computes power from the exact distribution of the F statistic."approximate"uses the closed form of Walter, Eliasziw and Donner (1998), available only formodel = "oneway".
Value
An object of class "power.htest", printed by
stats::print.power.htest(), with elements n, k, rho0, rho1,
sig.level, power, alternative, method and note.
Details
Exact power. For the one-way and the two-way consistency ICC with
complete data, the F ratio of the subject mean square to the error mean
square is a scaled central F variable whatever the true ICC \(\rho\):
$$F \sim \frac{1 + (k-1)\rho}{1 - \rho} F_{n-1, \nu_2},$$
with \(\nu_2 = n(k-1)\) (one-way) or \((n-1)(k-1)\) (two-way). The
test of \(H_0: \rho = \rho_0\) (McGraw & Wong, 1996) divides the F ratio
by the same factor at \(\rho_0\), so its power is a single F
probability (Donner & Eliasziw, 1987). Non-integer n is allowed, as in
stats::power.t.test(); round up to the next whole number of subjects.
Approximate power uses the closed form of Walter, Eliasziw and Donner (1998), $$n = 1 + \frac{2k (z_{1-\alpha} + z_{1-\beta})^2}{(k-1)(\log C_0)^2}, \quad C_0 = \frac{1 + k\theta_0}{1 + k\theta_1}, \quad \theta = \frac{\rho}{1 - \rho},$$ with \(\alpha/2\) in place of \(\alpha\) for a two-sided test. Walter et al. (and the PASS software) write n for the number of measurements per subject and k for the number of subjects; here n is always the number of subjects and k the number of measurements per subject. The exact method is preferred; the approximation is provided to reproduce published tables.
Two-sided tests. When solving for rho1 with
alternative = "two.sided", the solution above rho0 is returned; use
alternative = "less" (with the significance level halved) for the one
below.
Average-measure ICCs. The average-measure ICC is the Spearman-Brown
projection of the single-measure ICC to k measurements,
\(k\rho / (1 + (k-1)\rho)\), so a test about ICC(k) or ICC(C,k) is the
same F test as the test about the corresponding single-measure ICC, and
its interval is the projection of the single-measure interval. With
unit = "average" the calculations are therefore exact, not
approximations; k must be given because it defines the quantity being
planned for.
Missing measurements (approximate). With missing = p > 0, the
calculation uses the observed-data quantities that
icc_test(method = "reml") uses for incomplete data:
\(N = nk(1 - p)\) observations, \(\bar{k} = N/n\) measurements per
subject in the scale factor of the F ratio and in the interval, and error
degrees of freedom \(N - n - k + 1\) (two-way) or \(N - n\) (one-way).
This is an approximation: the F distribution is exact only for complete
data. In simulations of the REML analysis (one-way and two-way ICCs, 15
or 40 subjects, 3 or 5 items, 15% or 30% of measurements missing
completely at random or 30% at random depending on the first
measurement; 1000 replicates per setting), the approximate power was
within 0.035 of the simulated power (Monte Carlo SE 0.016) and the
approximate median interval width within 2.2% of the simulated median.
The REML test itself was slightly liberal with 30% missing (type I error
up to 0.069 missing completely at random and 0.073 at random, for a
nominal 0.05), which the simulated power includes. A warning is given
above 30% missing. The calculation assumes each subject keeps at least
one measurement.
Planning other designs. These functions are exact only for the one-way and two-way consistency ICCs with complete, normally distributed data. They can still guide the planning of other ICC studies, as long as the direction of the error is kept in mind:
Absolute agreement ICC (ICC(A,1), and the CCC for two methods). Not supported exactly: its test has no exact F distribution, and because its denominator degrees of freedom depend on the sample, its power "cannot be determined exactly" (McGraw & Wong, 1996, footnote 3). When the items (trials, raters, methods) differ little systematically, ICC(A,1) is close to ICC(C,1) and the consistency calculation is a good guide. When they differ, the agreement test and interval also depend on the item mean square, which has only k - 1 degrees of freedom: power is lower and intervals wider than the consistency calculation says, most of all with 2 or 3 items. Treat the consistency result as a lower bound on the number of subjects; simulation would be needed for a precise answer.
Missing measurements. Use
missingfor measurements missing here and there (see below). For subjects who will be lost entirely, plan for the subjects who complete the study and recruit \(n / (1 - d)\) for an expected dropout d.Non-normal data. The exact calculations assume normality. With skewed or heavy-tailed data the F-based intervals are wider and cover less than planned (see
icc_test()andreli_err_test()for simulations), so allow a margin or plan for the bootstrap with a larger sample.
References
Donner, A., & Eliasziw, M. (1987). Sample size requirements for reliability studies. Statistics in Medicine, 6(4), 441-448. doi:10.1002/sim.4780060404
McGraw, K. O., & Wong, S. P. (1996). Forming inferences about some intraclass correlation coefficients. Psychological Methods, 1(1), 30-46. doi:10.1037/1082-989X.1.1.30
Walter, S. D., Eliasziw, M., & Donner, A. (1998). Sample size and optimal designs for reliability studies. Statistics in Medicine, 17(1), 101-110. doi:10.1002/(SICI)1097-0258(19980115)17:1<101::AID-SIM727>3.0.CO;2-E
See also
precision_icc() for the sample size for a confidence interval
of a given width; icc_test() for the analysis.
Examples
# Subjects needed to show an ICC above 0.6 when it is 0.8, with 2 trials
power_icc(rho0 = 0.6, rho1 = 0.8, k = 2, power = 0.8,
alternative = "greater")
#>
#> Power calculation for the one-way ICC, ICC(1) (exact F distribution)
#>
#> n = 38.90078
#> k = 2
#> rho0 = 0.6
#> rho1 = 0.8
#> sig.level = 0.05
#> power = 0.8
#> alternative = greater
#>
#> NOTE: n is the number of subjects; round up to a whole number.
#> n = number of subjects, k = measurements per subject
#>
# Power with 30 subjects and 3 trials
power_icc(n = 30, k = 3, rho0 = 0.5, rho1 = 0.75, alternative = "greater",
model = "twoway")
#>
#> Power calculation for the two-way consistency ICC, ICC(C,1) (exact F distribution)
#>
#> n = 30
#> k = 3
#> rho0 = 0.5
#> rho1 = 0.75
#> sig.level = 0.05
#> power = 0.8835267
#> alternative = greater
#>
#> NOTE: n = number of subjects, k = measurements per subject
#>
# Trials needed with 20 subjects
power_icc(n = 20, k = NULL, rho0 = 0.5, rho1 = 0.8, power = 0.9,
alternative = "greater")
#>
#> Power calculation for the one-way ICC, ICC(1) (exact F distribution)
#>
#> n = 20
#> k = 3
#> rho0 = 0.5
#> rho1 = 0.8
#> sig.level = 0.05
#> power = 0.9
#> alternative = greater
#>
#> NOTE: n = number of subjects, k = measurements per subject
#>
